logo
Welcome to Changzhou Bextreme Shell Motor Technology Co.,Ltd
+86 18152874275

OWP-BL2000H-D3-1 DC48V Shielded Centrifugal Pump: Ideal for Liquid-to-Air Cooling Systems & CDU

Basic Properties
Place of Origin: China
Brand Name: Bextreme Shell
Model Number: OWP-BL2000H-D3-1
Trading Properties
Minimum Order Quantity: 1
Price: Negotiable
Payment Terms: T/T,Western Union
Supply Ability: 10000pcs/month
Product Summary
275L/min 30m Head DC48V Shielded Centrifugal Pump: Ideal for Liquid-to-Air Cooling Systems & CDU Product Overview The OWP-BL2000H-D3-1 is a horizontal single-stage centrifugal shielded electronic pump designed for Liquid-to-Air cooling systems and CDU applications. It delivers 275 L/min flow rate at ...

Product Details

Highlight:

DC48V shielded centrifugal pump

,

BLDC water pump for cooling systems

,

centrifugal pump with liquid-to-air cooling

Product Name: PMSM Brushless Coolant Pump
Type: Shield Pump
Model No.: OWP-BL1500H-D3-1
Material: Cast Aluminum
Working Voltage: DC 48V
Application: Coolant Circulation System
Service Life: More Than 40000h
Protection Grade: IP 67
System Pressure Rating: -0.9-10 Bar
Performance: Q=275L/min @H=30m
Product Description
275L/min 30m Head DC48V Shielded Centrifugal Pump: Ideal for Liquid-to-Air Cooling Systems & CDU
Product Overview

The OWP-BL2000H-D3-1 is a horizontal single-stage centrifugal shielded electronic pump designed for Liquid-to-Air cooling systems and CDU applications.

It delivers 275 L/min flow rate at 30m head with DC48V power supply, featuring IP67 protection and cast aluminum wetted parts.

This pump integrates brushless permanent magnet synchronous motor technology, ensuring high efficiency and a service life of over 40,000 hours.

It supports deionized water and antifreeze media, with multiple protection functions for reliable operation in harsh environments.

Cause

Liquid-to-Air cooling systems and CDUs face critical challenges in high-power heat dissipation scenarios.

Leakage risks from traditional pumps threaten system safety, especially when handling expensive or sensitive cooling media.

Inefficient motors lead to high energy consumption and shortened service life, increasing operational costs.

Extreme temperature fluctuations (-40℃~60℃) and humidity (5~95%) demand robust environmental adaptability.

Lack of comprehensive protection functions often results in pump damage from dry running, overvoltage, or reverse connection.

Solution

The centrifugal shielded design eliminates leakage risks by integrating rotor and impeller in a sealed chamber.

Brushless permanent magnet synchronous motor achieves higher efficiency than conventional motors, reducing energy loss.

Constant flow control maintains stable cooling performance regardless of system pressure changes.

Multiple protection mechanisms prevent pump failure: reverse connection, dry running, overvoltage, overcurrent, overload and overtemperature protection.

Cast aluminum wetted parts offer excellent corrosion resistance and structural stability.

IP67 protection rating ensures reliable operation in dusty, humid, or water-exposed environments.

Specifications
Parameter Details
Model OWP-BL2000H-D3-1
Product Type Horizontal Single-Stage Centrifugal Shielded Electronic Pump
Rated Voltage DC48V
Operating Voltage Range DC42~58V
Protection Level IP67
Weight 4.5Kg
Rated Power 2500W
Flow & Head 275 L/min @ 30m Head
Service Life ≥40000h
Noise Level ≤70dB (measured 1 meter away from pump)
System Pressure -0.9Bar~10Bar
Maximum Applicable Altitude ≤3000m
Operating Ambient Humidity 5~95%
Ambient Temperature -40℃~60℃
Medium Temperature -30℃~60℃
Communication Method RS485
Wetted Component Material Cast Aluminum
Inlet & Outlet φ38mm inner flow diameter, φ64mm quick-install clamp chuck
Application
Liquid-to-Air Cooling Systems
  • The pump’s 275 L/min flow rate and 30m head efficiently circulate coolants in high-power heat exchange systems.
  • Wide temperature adaptation suits both indoor and outdoor Liquid-to-Air heat dissipation equipment.
  • IP67 protection resists dust and moisture, suitable for industrial and data center cooling environments.
  • Quick-connect chuck design simplifies installation, disassembly and routine loop maintenance.
CDU (Coolant Distribution Unit)
  • Stable constant flow control ensures uniform coolant distribution across multiple cooling nodes.
  • RS485 communication supports real-time monitoring and remote system linkage.
  • Working pressure range meets the operation requirements of high-density liquid cooling CDU equipment.
  • Cast aluminum contact parts operate stably with deionized water or antifreeze coolant.
How It Works
  • The shielded centrifugal structure separates the motor stator from coolant to realize zero-leakage operation.
  • The brushless permanent magnet synchronous motor converts electric energy into rotating mechanical energy efficiently.
  • High-speed rotating impeller generates centrifugal force to drive continuous coolant circulation.
  • Built-in constant flow algorithm stabilizes flow output under varying system resistance.
  • RS485 interface realizes real-time data upload and remote parameter adjustment.
  • Built-in detection circuits activate protective shutdown once abnormal operating conditions are detected.
How To Choose
  1. Confirm Host Heat Dissipation Power

    Adopt the standard ratio: 1.5 L/min flow corresponds to 1 KW heat dissipation capacity.

    With the maximum available flow of 275 L/min, the pump can support hosts with heat load up to around 183 KW.

    Select OWP-BL2000H-D3-1 for Liquid-to-Air systems or CDUs whose total heat dissipation ≤ 183 KW.

  2. Confirm Power Supply Condition

    Check that the on-site power supply stays within DC42V ~ 58V working voltage range.

    Avoid excessive voltage fluctuation which may trigger built-in electrical protection.

  3. Verify Coolant Medium

    This pump is designed for deionized water and antifreeze only.

    Confirm the coolant temperature stays within -30℃ ~ 60℃ during long-term operation.

  4. Check Environmental Limits

    Verify ambient temperature, humidity, altitude and system pressure match product specifications.

    Do not use the pump beyond defined environmental boundaries to avoid shortened service life.

  5. Confirm Interface and Installation Space

    Match pipeline layout with φ64mm quick-install chuck interface.

    Reserve sufficient installation space for the 4.5kg horizontal mounted pump.

FAQ
  • Q: What is the production lead time of OWP-BL2000H-D3-1?

    A: The standard lead time is 20 working days after formal order confirmation.

  • Q: Can this electronic coolant circulation pump accept customized modifications?

    A: Yes, customized solutions are available according to your actual system requirements.

  • Q: What about warranty, service life and technical support?

    A: The pump enjoys a 2-year warranty with a service life ≥40000 hours; our team offers fast-response technical support.

Related Products

Send An Inquiry